Mon–Fri 06:00–19:00 CT · spot volume dispatch 24/7dispatch@cubictransport.comDimensional engineCarrier rule matrix
Request spot rate
  1. Home
  2. Carrier cube rules
  3. R+L & TForce rules

Carrier cube rules · RLCA 100 & UPGF 102

R+L Carriers (RLCA 100) & TForce Freight (UPGF 102) Cubic Capacity & Linear Foot Penalty Comparison

R+L Carriers and TForce Freight both use the single 750 cu ft tier. The difference is on the floor: R+L publishes a 12 linear foot rule with a weight floor per linear foot that can dwarf a cube-based synthetic weight. This page puts the two side by side on the same load.

R+L tariff
RLCA 100
TForce tariff
UPGF 102
Cube trigger
≥ 750 cu ft under 6 PCF
R+L linear foot
≥ 12 LF
R+L LF floor
750–1,000 lbs per LF
Ceiling imputation
96 in
A vibrant red semi-truck travels through a desert highway with mountain views in Nevada.
Photo: Quintin Gellar / Pexels

Two carriers, one cube tier

Neither R+L nor TForce publishes the 350 cu ft tier used by XPO, Saia, ABF and Estes. Both test a shipment at 750 cu ft under 6 PCF, both impute 96 in on freight that cannot carry top weight, and both re-rate on a synthetic weight with a correction or reclassification fee. The table lines up what the rules tariffs say:

ProvisionR+L CarriersTForce Freight
Rules tariffRLCA 100 (cubic capacity and linear foot rule)UPGF 102 (cubic capacity and density rules)
Cube trigger750 cu ft or more under 6 PCF750 cu ft or more under 6 PCF
350 cu ft tierNot publishedNot published
Linear foot trigger12 LF or moreNot listed in the rule we reviewed
Height imputationFull trailer height when freight cannot support top weight96 in on non-stackable skids
Penalty mechanismSynthetic weight floor of 750–1,000 lbs per LF, plus W&I correction chargeSynthetic weight adjustment plus reclassification fee

TForce Freight's tariff prefix, UPGF, dates from its time as UPS Ground Freight. Our engine screens TForce loads at 12 LF as well, as a conservative check; whether a TForce linear foot provision applies to your load is a question for the current UPGF 102 issue.

Run your load against R+L or TForce

Handling units
How the badge reads
  • Safe — tariff cube, density and linear feet stay under the carrier's cube and linear-foot rules.
  • Tier 1 — 350 cu ft or more under 3 PCF (XPO, Saia, ABF, Estes): synthetic weight of 6 lbs per tariff cubic foot.
  • Re-bill — 750 cu ft or more under 6 PCF, or linear feet at the carrier's rule: book volume LTL or direct partial truckload.
cu ft = L×W×H ÷ 1,728 · PCF = lbs ÷ cu ft non-stackable or > 60 in → cubed at 96 in LF = rows × length ÷ 12 (2 across)
Lock direct PTL / volume LTL rate

R+L and the weight floor per linear foot

R+L's linear foot rule is the provision that changes the arithmetic. Once a shipment occupies 12 LF or more, the rated weight can be set at a floor of 750 to 1,000 lbs for each linear foot, depending on the provision in force. That is a floor-space charge expressed in pounds:

R+L linear foot floor = linear feet × 750 to 1,000 lbs
Cube-based floor = tariff cu ft × 6 lbs
Rated weight = the greater of scale weight and the applicable floor
Linear feetFloor at 750 lbs / LFFloor at 1,000 lbs / LF
129,000 lbs12,000 lbs
1612,000 lbs16,000 lbs
2015,000 lbs20,000 lbs
2418,000 lbs24,000 lbs

For dense freight these floors rarely matter: 12 LF of palletised canned goods already weighs more than 9,000 lbs. For light freight they are severe. A 12 LF load of 2,000 lbs of foam can be rated at four and a half times its weight or more.

Worked example: six non-stackable 48×48 skids

Six 48×48 skids of rotomolded plastic housings, 70 in tall, 320 lbs each, marked do not stack. Lane length 850 miles.

MeasureCalculationResult
Actual cube48 × 48 × 70 ÷ 1,728 × 6560.0 cu ft
Total weight320 × 61,920 lbs
Actual density1,920 ÷ 560.03.43 PCF (Class 250)
Tariff cube at 96 in48 × 48 × 96 ÷ 1,728 × 6768.0 cu ft
Tariff density1,920 ÷ 768.02.50 PCF
Linear feet3 rows × 48 in ÷ 1212 LF
Cube trigger (both carriers)768 ≥ 750 and 2.50 < 6Fires by 18 cu ft
Cube-based floor768.0 × 64,608 lbs
R+L linear foot floor12 × 750 to 12 × 1,0009,000–12,000 lbs

Both carriers' cube tier fires because the 96 in imputation adds 208 cu ft of phantom cube to a 560 cu ft load. At TForce the synthetic weight of 4,608 lbs applies. At R+L the 12 LF rule also fires, and if the linear foot floor governs, the rated weight is 9,000 lbs or more, close to five times the scale weight.

Indicative engine figures, which model the 6 PCF floor only: about $802 rated cleanly, about $1,315 re-rated, about $750 as a spot volume LTL quote and about $878 on a direct partial truckload. On R+L the linear foot floor would push the re-rate well above the engine figure. These are planning numbers, not quotes.

Four, five or six skids on each carrier

Skids (48×48×70, non-stackable, 320 lbs)Tariff cubeTariff PCFLinear feetR+LTForce
4512.02.508ClearClear
5640.02.501212 LF rule firesCube clear; check UPGF 102 for space rules
6768.02.5012Cube and 12 LF fireCube fires

The five-skid row is where the two carriers part. Five 48×48 skids sit in three rows, two across with one alone, so they take the same 12 LF as six. At R+L that is enough for the linear foot rule; at TForce the cube is 110 cu ft short of 750 and the load can rate on scale weight unless a separate space provision applies. Indicative engine figures for five skids: about $668 clean and about $1,107 if a rule fires. Four skids clear both carriers at about $534 clean.

The lesson is that an odd skid count wastes floor. Five skids pay for six positions on the trailer floor; if the sixth skid of the same order ships later, it may cost more than the floor it would have filled.

Freight that hits the R+L linear foot floor hardest

The per-linear-foot floor is a weight floor, so it bites in proportion to how light the freight is for the floor it takes. A quick way to see the exposure is to compare actual pounds per linear foot with the 750 lbs floor:

Load (single high, 2 across)Linear feetWeightActual lbs per LFFloor at 750 lbs / LF
6 skids foam packaging, 120 lbs each12720 lbs609,000 lbs
6 skids 48×48 housings, 320 lbs each (example)121,920 lbs1609,000 lbs
8 skids cabinets, 240 lbs each161,920 lbs12012,000 lbs
6 skids boxed hardware, 1,600 lbs each129,600 lbs8009,000 lbs

Only the last load, dense hardware, already weighs more than the floor; the rule costs it nothing. Every light load in the table would be rated at many times its scale weight if the linear foot floor governs. For foam, packaging, plastics and assembled furniture past 12 LF, R+L is rarely the right LTL carrier, and a volume quote or partial truckload is the safer tender. The fiberglass and plastics page covers that commodity group in detail.

Choosing between R+L, TForce and a non-LTL mode

  • Under 12 LF and under 750 tariff cu ft: both carriers rate on scale weight. Pick on price and transit.
  • 12 LF or more, under 750 tariff cu ft, light freight: R+L's linear foot floor makes it the riskier choice; TForce may rate cleanly, subject to the current UPGF 102.
  • 750 tariff cu ft or more under 6 PCF: both re-rate. A direct partial truckload or spot volume LTL quote will usually win.

For long, light freight between 12 and 15 LF, Old Dominion is worth a look, since its linear foot line sits at 15 LF. The full matrix is below.

CarrierRules tariff itemCube / LF triggerHeight imputationRe-rating mechanism
Old DominionODFL 100 Item 610-1≥ 750 cu ft under 6 PCF; ≥ 15 LFNon-stackable or 48–60 in+ units cubed to 96 in6 lbs × cu ft at class 125/150 or minimum floor; FAK discount voided
XPOCNWY 199 Item 233Tier 1 ≥ 350 cu ft under 3 PCF · Tier 2 ≥ 750 cu ft under 6 PCF"Do not stack", cone-top or > 60 in cubed to 96 inCube × 6 PCF at applicable class with restricted discount, or flat cubic minimum
SaiaSAIA 170 Item 111≥ 350 cu ft under 3 PCF or ≥ 750 cu ft under 6 PCFForced 96 in on non-stackable / irregular topsSynthetic density weight floor + W&I inspection fee
FedEx FreightFXF 100 series≥ 750 cu ft under 6 PCF, or 10–15+ LFOver 60 in or non-stackable calculated at 96 inMinimum density weight or linear-foot minimum charge
ABF FreightABF 111 Item 616 / 611≥ 350 cu ft under 3 PCF or ≥ 750 cu ft under 6 PCFFull trailer height (96–102 in) when top-loading restricted6 lbs/cu ft synthetic weight or cubic minimum schedule
EstesEXLA 105≥ 350 / ≥ 750 cu ft low-density; 12–15 LFNon-stackable assessed full 96 inRe-billed as capacity load / volume rate, contract discount stripped
R+L CarriersRLCA 100≥ 750 cu ft under 6 PCF or ≥ 12 LFFull height imputed when freight cannot bear top weight750–1,000 lbs per LF synthetic floor + W&I correction
TForce FreightUPGF 102≥ 750 cu ft under 6 PCF96 in imputation on non-stackable skidsSynthetic weight adjustment + reclassification fee

Summary of carrier rules tariff provisions as indexed by Cubic Transport. Carriers reissue rules tariffs; the current issue on the carrier's site governs any bill.

Checking RLCA 100 and UPGF 102 before you dispute

R+L reissues RLCA 100 and TForce reissues UPGF 102 like every carrier reissues its rules tariff, and the current issue governs. The 750 to 1,000 lbs per linear foot range on this page reflects the provisions we reviewed, not a promise of the figure in force on your ship date. Before disputing, pull the issue in force and read the cubic capacity, density and linear foot provisions.

  1. Request the inspection record and dimensioner photos.
  2. Identify the rule used. On R+L, check whether the re-rate used the cube floor or the linear foot floor; the numbers differ by thousands of pounds.
  3. Check the row count. Linear feet should follow from unit length and how many units fit across. A miscounted row is a common winner.
  4. Rebuild tariff cube and density from the scanned dimensions.

The W&I dispute guide has the filing steps.

Frequently asked questions

Do R+L and TForce have a 350 cu ft cubic rule?
Not in the RLCA 100 and UPGF 102 provisions we reviewed. Both use a single 750 cu ft trigger under 6 PCF.
What is the R+L linear foot weight floor?
Once a shipment occupies 12 LF or more, R+L can set the rated weight at 750 to 1,000 lbs per linear foot. On a 12 LF load that is 9,000 to 12,000 lbs, whatever the scale says.
Does TForce Freight have a linear foot rule?
The UPGF 102 cubic capacity and density rule we reviewed lists a cube trigger, not a linear foot trigger. Our engine screens TForce at 12 LF as a precaution; check the current issue for any space-based provision.
Why is the TForce rules tariff called UPGF 102?
TForce Freight was formerly UPS Freight, and its rules tariff kept the UPGF prefix. UPGF 102 holds the cubic capacity and density rules.
Which carrier is better for light, long freight?
Under 750 tariff cu ft, TForce may rate cleanly where R+L applies its 12 LF floor. Above 750 cu ft under 6 PCF both re-rate, and a direct partial truckload usually costs less.
Three white cargo trailers parked at an industrial shipping dock under clear blue skies.

Before the carrier's dimensioner sees it

Price it as volume LTL and direct PTL side by side

Send pallet count, dimensions and weight. The rate desk checks the cube rule, quotes both modes and books the one without a re-bill.

Request spot rate